Dental implants & abutments
Implant systems, multi-unit abutments, and surgical kits with UDI-traceable packaging for oral surgery and restorative teams.
View implant catalog →Dental implants · CAD/CAM · oral surgery
Compare implant systems, scan-to-mill cycle time, and sterilization capacity before a value-analysis committee freezes the shortlist. Every figure below is a review band for procurement planning, not a universal model claim.
Procurement baseline
Use these tabs to frame RFQ questions. Confirm torque ranges, scan accuracy claims, cycle parameters, and intended use in the current IFU, 510(k) summary, and quotation. Figures are planning bands, not audited clinical success rates.
| Parameter | Review envelope |
|---|---|
| Primary decision metric | Connection type, platform diameter range, and torque band disclosed in IFU for the indication under review |
| Traceability | UDI-DI / UDI-PI on implant and abutment packaging; GUDID lookup for lot-level recall readiness |
| Quality evidence | DHF / DMR excerpts, biocompatibility (ISO 10993), ISO 14971 risk file references on request |
| Regulatory phrasing | FDA cleared (510(k)) where required; CE marked under MDR 2017/745 as applicable — never generic "FDA approved" for 510(k) devices |
| GPO / contracting | Premier, Vizient, HealthTrust contract IDs confirmed in quotation package when applicable |
| Parameter | Review envelope |
|---|---|
| Primary decision metric | Chairside scan-to-design-to-mill minutes and remake drivers for the indicated restorative workflow |
| Connectivity | Practice management export; DICOM for CBCT where applicable; SBOM for networked controllers |
| Imaging dose protocol | kVp / mA / FOV bands and ALARA checklist for CBCT evaluation — confirm in modality IFU |
| Service assumption | Scanner / mill calibration interval, remote diagnostics scope, spare delivery SLA |
| Cybersecurity | FDA premarket cybersecurity guidance alignment, coordinated disclosure window, patch cadence |
| Parameter | Review envelope |
|---|---|
| Sterility assurance | SAL 10⁻⁶ claims only where labeled validated process applies; ISO 11607 packaging evidence on request |
| Reprocessing path | Steam (ISO 17665), EO (ISO 11135), or gamma (ISO 11137) — map to AAMI ST91 / IFU, not assumed interchangeable |
| Single-use vs reusable | Score per-case cost, reprocessing labor, cross-contamination liability, and landfill impact in the same TCO sheet |
| Lifecycle window | 7–10 year TCO = capital + service + consumables + downtime + training + decommissioning |
| Capital structure | Outright purchase / operating lease / per-procedure options disclosed in quotation, not website pricing |
Product families
Three evaluation lanes buyers typically freeze before capital approval. Confirm market availability and regulatory status in current product documentation.
Implant systems, multi-unit abutments, and surgical kits with UDI-traceable packaging for oral surgery and restorative teams.
View implant catalog →
Intraoral scanners, design software handoffs, and chairside milling with documented nest rules and calibration intervals.
View digital catalog →
Treatment units, imaging peripherals, and Class B autoclaves sized for instrument set turnaround in multi-chair practices.
View operatory catalog →Evidence path
Map implant diameter, length, and connection to the labeled indication — not marketing brochure photos.
Require UDI-DI search paths and 24-hour recall bulletin sync before stocking multi-chair inventory.
Request ISO 10993 endpoints relevant to tissue contact duration — cytotoxicity through implantation as applicable.
Test practice-management export, DICOM for CBCT, and HL7 FHIR observation push where networked monitors apply.
Separate single-use disposables from reusable trays with validated steam / EO / gamma routes and labor minutes.
Lock MTBF / MTTR planning numbers, loaner kits, and FSE coverage into the service tier before capital signature.
Figures are educational procurement planning indicators, not audited Zimmer Biomet installed-base, revenue, or clinical outcome claims. Confirm contract metrics in the quotation package.
Prepare a scoped request
A focused request separates catalog-level information from configuration-specific facts required by materials management and value analysis.